This line card may be used in slots 0-7 and 12-19 of M3-CLOS-ENCL or M3-CLOS-ENCL-B enclosures.
Front-panel ports (16): Standard Myrinet-2000 fiber ports: each 2.0+2.0 Gb/s data rate, 2.5+2.5 GBaud 8b/10b-encoded signaling. The optical-fiber transceivers accept LC-connectorized 50/125 multimode duplex fiber up to 200m in length. This is a Class 1 Laser Product (no biological hazard). The optical signaling is at a wavelength centered at 850nm.
Backplane ports (16): Standard Myrinet-2000 serial ports: each 2.0+2.0 Gb/s data rate, 2.5+2.5 GBaud 8b/10b-encoded signaling, on the backplane connectors.
Switch: Myricom XBar32 chip with ports 0-15 connected to the backplane ports, and ports 16-31 connected to the front-panel optical-fiber ports. The front-panel ports are labeled 16-31 corresponding to the XBar32 port number.
Microcontroller functions: Self-test, board identification, voltage monitoring, temperature monitoring (upstream & downstream in the air flow), transceiver monitoring and control, and XBar32 scan path functions. All status information is reported on demand through the serial link (to an M3-MONITOR monitoring line card). The µC will shut off the line-card power except for the µC section on over-temperature (greater than 55C) or other fault conditions. The µC controls a Status LED on the front panel: Off: not operating; Green: operating. Yellow: fault.
Power requirements: +12V input power @ 1.5A (18W) maximum. The line card is hot-swappable.
Physical characteristics: 9U-220mm card per IEEE 1101.10, with specialized connectorization. Weight 1.6 pounds (730g).
Environmental limits: Operating: Temperature 15C to 50C up to 10,000 foot altitude. Relative humidity 15% to 80% @ 50C, non-condensing. Storage: Temperature -40C to 70C. Relative humidity 90% @ 65C.
Regulatory Approvals: When properly installed in a Myricom M3-CLOS-ENCL or M3-CLOS-ENCL-B enclosure, the line card is fully compliant with EN55024 (1998), EN55022 Class A (1998), VCCI Class A (May 1999), FCC Part 15 Subpart B Class A, CISPR 22/85 Class A, ICES-003 Class A (ANSI C63.4 1992), and AS/NZS 3548 Class A (w/A1 & A2 1997). (View the EMC test report.)
![]()
Last updated: 7 January 2007