M3-E16, M3-E32, M3-E64, M3-E128

Enclosures for Myrinet-2000 Switches & Switch Networks

Please see this Guide to Myrinet-2000 Switches and Switch Networks for information about the installation and the principles of operation of this family of products. This page is a summary of specification information.

This family of enclosures provides the mechanical housing, power, cooling, and a built-in backplane network into which you can plug Myrinet-2000-switch line cards. The top line-card slot is reserved for an M3-M monitoring line card. The remaining slots are used for port line cards. Any port line card manufactured by Myricom can be used in any port-line-card slot of any enclosure. The enclosures differ in their height and number of slots in order to allow a choice of enclosure to best fit the application.

  M3-E16 M3-E32 M3-E64 M3-E128
Rack-mount height 2U 3U 5U 9U
Number of port-line-card slots 2 4 8 16
Maximum number of front-panel Myrinet ports (at 8 per line card) 16 32 64 128


M3-E128 without line cards, allowing a view of part of the backplane


Specifications

Physical:

  M3-E16 M3-E32 M3-E64 M3-E128
Height (1U = 1.75 inches = 44.45 mm) 2U 3U 5U 9U
Weight without line cards 5.3 kg 5.5 kg 10 kg 21 kg
Weight with line cards in all slots 7.0 kg 8.3 kg 15 kg 31 kg
Large-scale mechanical drawing GIF, 47KB GIF, 30KB GIF, 60KB GIF, 75KB

Enclosures are normally shipped assembled and tested with line cards in the configuration specified by the customer.

Note on the mechanical drawings: These drawings are provided only for installation planning. The metal chassis of these enclosures are produced for Myricom by several different vendors. There may be minor differences in the appearance, such as the grill-hole patterns, in the chassis manufactured by different vendors. However, the dimensions given in the drawings are the same for all vendors.

Environmental:

Thermal and Cooling:

  M3-E16 M3-E32 M3-E64 M3-E128
Fans on fan tray 4 60mm 3 92mm 4 92mm 8 92mm
Total air flow 30 cfm 60 cfm 120 cfm 240 cfm
Maximum BTU/hour with line cards in all slots 490 840 1680 3360

Power:


  M3-E16 M3-E32 M3-E64 M3-E128
Maximum total power with line cards in all slots 140 W 240 W 480 W 960 W
Maximum input current @ 100-127 V~ 1.4A 2.4A 4.8A 9.6A
Maximum input current @ 200-240 V~ 0.7A 1.2A 2.4A 4.8A

Safety Approvals:

M3-E16, M3-E32, M3-E64, and M3-E128 are certified by TUV of North America, Inc., in accordance with the IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), CB Scheme (view the CB Certificate, 216KB jpg file). In addition, TUV certified these products to the US and Canadian safety standards (view the cTUVus Certificate, 163KB jpg file).

EMC Approvals:

The following configurations are within Class A limits for emission of and susceptibility to electromagnetic interference (EMI):

CE Declaration of Conformity